Spain We present the case
of a patient 66 years old who was treated with argon laser twelve years
ago because of a giant retinal tear without retinal detachment. Ten years
later he presented a cataract and was operated with Phaco and posterior
IOL implant into the capsular bag. Two years later the patient suffered
a spontaneous dislocation of the IOL and capsular bag into the vitreous
cavity. In the operation we removed the dislocate IOL, inserted a new
anterior IOL and completed the vitrectomy showing the old giant retinal
tear.
|
||||||||||||||